Current Issue : July-September Volume : 2022 Issue Number : 3 Articles : 5 Articles
(1) Background: The purpose of this review is to study the role of radiomics as a supporting tool in predicting bone disease status, differentiating benign from malignant bone lesions, and characterizing malignant bone lesions. (2) Methods: Two reviewers conducted the literature search independently. Thirteen articles on radiomics as a decision support tool for bone lesions were selected. The quality of the methodology was evaluated according to the radiomics quality score (RQS). (3) Results: All studies were published between 2018 and 2021 and were retrospective in design. Eleven (85%) studies were MRI-based, and two (15%) were CT-based. The sample size was <200 patients for all studies. There is significant heterogeneity in the literature, as evidenced by the relatively low RQS value (average score = 22.6%). There is not a homogeneous protocol used for MRI sequences among the different studies, although the highest predictive ability was always obtained in T2W-FS. Six articles (46%) reported on the potential application of the model in a clinical setting with a decision curve analysis (DCA). (4) Conclusions: Despite the variability in the radiomics method application, the similarity of results and conclusions observed is encouraging. Substantial limits were found; prospective and multicentric studies are needed to affirm the role of radiomics as a supporting tool....
(1) Background: The aim of this study was to determine the frequency and the pattern of post-procedural intracranial aneurysm contrast enhancement on high-resolution vessel wall magnetic resonance imaging (HR-VW MRI).We investigated the possible association between this imaging finding and factors such as time elapsed since embolization or aneurysm occlusion grade on baseline and follow-up imaging. (2) Methods: Consecutive patients presenting for follow-up after endovascular treatment of intracranial aneurysms were included. HR-VW MRI was acquired and interpreted independently by two radiologists. (3) Results: This study included 40 aneurysms in 39 patients. Contrast enhancement was detected in 30 (75%) aneurysms. It was peripheral in 12 (30.0%), central in 9 (22.5%), and both peripheral and central in 9 (22.5%) aneurysms. The statistical analysis did not reveal any relationship between follow-up period and the presence of contrast enhancement (p = 0.277). There were no statistically significant differences in the frequency of contrast enhancement between aneurysms with total occlusion and those with remnant flow on follow-up MR angiography (p = 0.850) nor between aneurysms with different interval changes in the aneurysm occlusion grade (p = 0.536). Multivariate analysis did not demonstrate aneurysm size, ruptured aneurysm status, nor initial complete aneurysm occlusion to be a predictor of contrast enhancement (p = 0.080). (4) Conclusions: Post-procedural aneurysm contrast enhancement is a common imaging finding on HR-VW MRI. The clinical utility of this imaging finding, especially in the prediction of aneurysm recurrence, seems limited. The results of our study do not support routine use of HR-VW MRI in the follow-up of patients after endovascular treatment of intracranial aneurysms....
Late‐onset Rasmussen encephalitis (LoRE) is a rare unihemispheric progressive inflammatory disorder causing neurological deficits and epilepsy. The long‐term radiological evolution has never been fully described. We retrospectively analyzed the MR images of 13 LoRE patients from a total of 136 studies, and searched for focal areas of volume loss or signal intensity abnormality in grey matter or white matter. Each subject had a median of nine MRI studies (IQR 7– 13). Frontal and temporal lobes were the most affected regions (13/13 and 8/13, respectively) and showed the greatest worsening over time in terms of atrophic changes (9/13 and 5/8, respectively). A milder cortical atrophy was found in the insular and parietal lobes. The caudate nucleus was affected in seven patients. Hyperintensities of grey matter and white matter on T2‐WI and FLAIR images were observed in all patients, and transiently in eight patients. In two cases out of the latter patients, these transient alterations evolved into atrophy of the same region. Disease duration was significantly associated with signal abnormalities in the grey matter at last follow‐up. LoRE MRI alterations are milder, and their progression is markedly slower compared to radiological findings described in the childhood form....
Background: Analyses of lymphoid organs are required to further elucidate the pathogenesis of inflammatory diseases like rheumatoid arthritis (RA). Yet, invasive tissue collection methods are scarcely applied, because they are often considered burdensome, although patients do not always consider invasive methods as a high burden. We aimed to investigate the perspectives of study participants undergoing ultrasound-guided inguinal lymph node (LN) needle biopsy sampling and determine the molecular and cellular quantity and quality of LN biopsies. Methods: Together with patient research partners, questionnaires were developed to evaluate the motives, expectations, and experiences of participants undergoing a LN biopsy. Healthy controls and RA(-risk) patients were asked to complete these questionnaires before and after the procedure. RNA and lymphocyte yields from obtained LN biopsies were also calculated. Results: We included 50 individuals, of which 43 (86%) reported their pre- and post-procedure experiences. The median reported pain on a 5-point Likert scale (1 not to 5 very painful) was 1. Interestingly, almost all (n = 32; 74%) study participants would undergo a second procedure and more than half (n = 23; 54%) would encourage others to take part in the LN biopsy study. Motives for current and future participation were mostly altruistic. Inguinal hematoma occurred frequently, but no other significant or unexpected complications ensued. The LN biopsies yielded sufficient and high-quality RNA and lymphocyte numbers. Conclusions: Ultrasound-guided inguinal LN biopsy sampling is well-tolerated, safe, and provides sufficient material for further molecular and cellular analyses. Our participants’ positive experiences endorse the application of this research tool to further elucidate the pathogenesis of RA and other inflammatory diseases....
Purpose: Intrinsic foot muscles maintain foot structural integrity and contribute to functional movement, posture and balance. Thus, assessing intrinsic foot muscle size and strength are important. Magnetic resonance imaging (MRI) has been shown to accurately image the individual muscles but is costly and time consuming. Ultrasound (US) imaging may provide an alternative that is less costly and more readily available. The purpose of this study was to investigate the validity and intratester reliability of US imaging in measuring intrinsic foot muscle size in comparison to MRI. Methods: US and MRI were employed to measure the intrinsic foot muscle size involving 35 participants (females = 13; males = 22). The scanned intrinsic foot muscles included the flexor hallucis brevis (FHB), abductor hallucis (ABDH), flexor digitorum brevis (FDB), quadratus plantae (QP) and abductor digiti minimi (ADM). Pearson product correlation (r), intraclass correlation coefficients (ICC), standard error of the measurement (SEm) and minimal detectable difference (MDD) were calculated. Results: High correlations were detected between the US and MRI cross-sectional area (CSA) measurements (r = .971 to 0.995). Test reliability was excellent for both MRI and US (ICC = 0.994 to 0.999). Limits of agreement between MRI and US measurements from ranged from 5.7 to 12.2% of muscle size. SEm values for US ranged from 0.026 to 0.044 cm2, while the SEm for MRI ranged from 0.018 to 0.023 cm2. MDD values for US ranged from 0.073 to 0.122 cm2, while MRI ranged from 0.045 to 0.064 cm2. Conclusions: US appears to be a valid and reliable alternative to MRI when measuring intrinsic foot muscle CSA. While US is less costly and more readily available, the MRI results were shown to be slightly more precise....
Loading....